How To Install a TOUGH GUN™ ThruArm™ MIG Gun Equipped with TOUGH GUN I.C.E.™ Technology onto a KUKA® KR5 HW Robot
 

  1. Remove the neck, consumables and conduit from torch.
  2. Slide the torch through robot wrist and conduit.
  3. Secure the torch on robot wrist.
  4. Secure the conduit with two clamps and M5 SHCS.
  5. Connect the torch to the feeder.
  6. Install the neck, liner and consumables. 

TOUGH GUN G2 Torch Installation

TOUGH GUN G2 Torch Installation